Tilt Power Controller (Self-Hold type)
TPC010100 / TPC010101 / TPC010103 / TPC010110 / TPC010111 / TPC010112 / TPC010113 / TPC010114
Function:Tilt detecting power control within a 360° radius
Certification: RoHS,Patent
Original Place: Taiwan
Function:Tilt detecting power control within a 360° radius
Certification: RoHS,Patent
Original Place: Taiwan
Please select which you want to ask the following product specifications:
*Model: |
Tilt Power Controller (Self-Hold type)
- Automatically Power Shut Off - After power on, when the controller tilts over a degree it will shut off the output power supply.
- Safety Protection after Recovering from Tilt Situation - After power on, when the controller tilts over a degree it will shut off the output power supply. When the controller recovers from tilt situation, the output power is still shut off until the user pushes the“reset”button.
Model |
TPC010100 |
TPC010101 |
TPC010103 |
TPC010110 |
TPC010111 |
TPC010112 |
TPC010113 |
TPC010114 |
Operating Angle | θ <15° | θ <30° | θ <20° |
θ <45° |
θ <30° |
θ <65° |
θ <20° |
θ <15° |
Installation Type |
Horizontal |
Horizontal |
Horizontal |
Vertical |
Vertical |
Vertical |
Vertical |
Vertical |
Electrical Characteristics
Technical Requirements | |
Input Power Voltage |
AC 110 V |
Input Power Frequency |
F=50~60 Hz |
Output Power Voltage/ Frequency |
(Same as input Voltage/Frequency) |
Maximum Current |
10.0A |
Maximum Loading (Walt) |
1200 W |
Static power consumption |
≦6W |
Absolute Maximum Rating(Ta=25℃)
Operating Temperature | Topr |
-25℃~+85℃ |
Storage Temperature |
Tstg |
-40℃~+85℃ |
- Only after wiring correctly, the user can energize the controller.
- After energizing the controller, when the controller tilts less than the specifications angle from horizontal/vertical direction, the controller will be regarded as in normal position. The controller will supply power to the controlled appliance. When the controller tilts more than the canonical angle from horizontal/vertical direction (shown in Fig.4), the controller will be regarded as in an abnormal position. The controller will shut off the power supply to the controlled appliance. In the meaning time, the self-holding circuit in the controller will be started.
- After the self-holding circuit being started, the controller will keep in “shut off” status and stop power supply to the controlled appliances. Even when the abnormal condition has been ruled out and returned to the original correct position, the circuit is still kept in the “shut-off” status.Only until the user pressing the RESET button, the self-holding circuit will be released and recover the power supply to the controlled appliances.
- In any time, shutting off the power and reenergizing the controller will release the self-holding circuit.
- Please do not exceed the rated load as there will be a risk of disabling the product function.
- In the circuit, the “RBS switch” should not be near the magnetic component (for example: transformers, etc.).
- For the continued product improvement as one of the company policy, specifications may change or update without notice. The latest information can be obtained through our sales offices. Normally, all products are supplied under our standard conditions.
Automatically power shut off for home appliances or sporting equipment.