Non-Contact Optical Liquid Level Switch-LLS060102 (6 level)

Other liquid level detection sensors will touch the liquid directly, incrustation will stick on the inter surface of containers and sensors easily which causes water pollution.  Different from other liquid level sensors, non-contact liquid level detecting module we make will be installed on the outer surface of the containers which will not touch the liquid and thus leave the liquid clean and non-polluted.
*Our module can be customized, should you have any requirements, please feel free to contact us know. (size, automatic refill function, etc)




  • Function: Non contact Liquid level detecting
  • In the actual use, when the liquid level is higher or lower than the sensing area height, there is corresponding TTL logic signal to each level change, respectively Auto calibration function included.
  • The module is used to detect the existence of liquid by sensing the capacitance, and the capacitance of liquid will be changed with temperature, especially water. Auto calibration will be started while sensing big changing of capacitance.
  • If the liquid will have been sensed the change in temperature, please be noted that the maximum sensing distance D will be also changed. Therefore, if fixed sensing distance, the sensed height of liquid level can vary due to the impact of liquid temperature. In practice, the change in the height of liquid level should be determined by actual measurement
  • Attention: This level sensor module uses the embedded sensing capacitance to detect the change of liquid level; therefore, it must keep all metal articles or human body influencing the capacitance far away from the sensing area to avoid the disoperation. There should be a certain distance between metal article or human body and sensing area. The distance should be determined by actual measurement.
  • The male connector ( pitchpitch:1.25mm ) and the wire are not included in the standard package. It needs to be purchased if required.
  • For customized design, it’s recommend that the line length between the sensing area and the main IC should not exceed 3 5cm.
  • Please do not exceed the rated load as there will be a risk of disabling the product function.
  • For the continued product improvement as one of the company policy, specifications may change or update without notice. The latest information can be obtained through our sales offices. Normally, all products are supplied under our standard conditions.


LLS060102 Non contact Liquid Level detecting Sensor Module - 6 levels


Liquid Level Changing and Signal Output

During usage, defining different liquid level, the level sensor module will send the logic signal.  The signal and the corresponding change of the liquid level will be shown as below :

  • When the liquid level is lower than the sensing area fixed height, the indicator light will be on and the logic signal is low (H).
  • When the liquid level is higher than/equal to the fixed height, the indicator light will be off and the logic signal is high (L)

** The installation place of the liquid level switch must be flat, and the liquid medium should be water. Insulating medium such as oil is not applicable.

** Maximum Sensing Distance D at 25 °C : About 7.0 mm from water to sensing area includes the thickness of container


Electrical Characteristic

Parameter SYM. Min. Typ. Max. Unit
Operating Voltage Vdd 2.5 5.0 5.5 Volt


Absolute Maximum Rating(Ta=25

Operating Temperature Topr 0℃ ~ +60
Storage Temperature
Tstg
-40℃ ~ +85